NI PXI-6713 8-Channel 12-Bit High-Speed Analog Output Module

The NI PXI-6713 is a high-speed analog output module designed for multichannel waveform generation, electronic stimulus, automated test, hardware-in-the-loop simulation, laboratory control, and production applications. The module provides eight voltage output channels with 12-bit digital-to-analog conversion and a maximum update rate of 1 MS/s per channel under supported operating configurations.

Each output channel provides a nominal ±10 V range and can also operate with compatible external-reference scaling. The outputs are DC coupled and support programmable static voltages, ramps, sine waves, arbitrary waveforms, simulated sensor signals, control profiles, and other analog stimulus patterns.

A 16,384-sample onboard FIFO supports buffered waveform generation and reduces dependence on continuous host-computer transfers. The PXI-6713 supports DMA, interrupt, and programmed I/O data transfers for integration into compatible NI-DAQ and NI-DAQmx application environments.

The module also includes eight TTL/CMOS-compatible digital I/O lines, two 24-bit counter/timers, programmable timing connections, and PXI backplane triggering resources. These additional functions support synchronized waveform generation, event control, external triggering, pulse generation, and coordination with compatible PXI measurement modules.

Features and Benefits of the NI PXI-6713

The NI PXI-6713 provides flexible analog stimulus and timing resources for professional users developing modular automated test and control systems.

  • Eight analog output channels: Generates multiple independent voltage signals from one compact PXI module.
  • 12-bit resolution: Provides one part in 4,096 digital-to-analog conversion resolution.
  • Maximum 1 MS/s update rate: Supports high-speed waveform generation on compatible channel configurations.
  • ±10 V output range: Provides bipolar voltage stimulus for compatible circuits, devices, sensors, and control systems.
  • External-reference support: Allows compatible external scaling of the analog output range.
  • 16,384-sample FIFO: Supports buffered waveform generation and repeated output sequences.
  • 20 V/µs slew rate: Supports rapid voltage transitions in compatible waveform and stimulus applications.
  • Eight digital I/O lines: Adds TTL/CMOS-compatible control, status, and synchronization capability.
  • Two 24-bit counter/timers: Supports compatible timing, event counting, frequency measurement, and pulse generation.
  • PXI synchronization resources: Supports coordinated operation with compatible digitizers, digital I/O modules, and measurement instruments.
  • Multiple data-transfer methods: Supports DMA, interrupts, and programmed I/O.
  • 68-pin I/O connector: Provides access to analog outputs, digital I/O, counters, triggers, reference inputs, and grounds.

High-Speed Analog Output

The PXI-6713 provides eight voltage outputs for applications requiring several programmable stimulus signals. Each channel can generate static levels or hardware-timed waveforms according to the selected application and software configuration.

The maximum update rate depends on the number of active channels and the selected transfer method. Up to five channels can operate at 1 MS/s using the onboard FIFO. The documented FIFO-based rate decreases to 952 kS/s with six active channels, 833 kS/s with seven channels, and 740 kS/s with all eight channels active.

Host-memory waveform generation can support 1 MS/s through six channels under the documented reference conditions. Host-memory performance depends on the controller, operating system, software, bus activity, and other installed modules.

Analog Output Performance

The analog outputs provide a 20 V/µs slew rate and a documented settling time of 3.0 µs to within ±0.5 LSB. These characteristics support controlled waveform generation and relatively fast transitions between output levels.

The module provides a maximum output impedance of 0.1 ohm and a maximum current drive of ±5 mA. Compatible passive loads can have capacitance up to 1,500 pF.

Each output includes short-circuit-to-ground protection. This protection should not be treated as permission to operate continuously into an unsuitable load or to exceed the documented voltage and current limits.

Digital I/O and Counter/Timer Functions

The PXI-6713 includes eight TTL/CMOS-compatible digital I/O lines. These lines can support device control, status monitoring, test-fixture operation, external handshaking, and synchronization with compatible equipment.

The module also includes two 24-bit up/down counter/timers. Available base clocks include 20 MHz and 100 kHz, with a documented maximum source frequency of 20 MHz.

Counter/timer resources can be used for compatible event counting, pulse generation, timing measurements, frequency measurements, and hardware-controlled test sequences.

PXI Timing and Triggering

The PXI-6713 supports hardware triggering for coordinated waveform operation. Analog output start, gate, and clock functions can use supported external or backplane timing signals.

The PXI implementation provides six backplane trigger lines, one PXI star-trigger resource, and one PXI clock connection. These resources help coordinate stimulus generation with compatible acquisition, switching, digital, and measurement modules installed in the same chassis.

Typical Applications

The NI PXI-6713 is suitable for professional applications such as:

  • Multichannel analog waveform generation
  • Automated electronic testing
  • Hardware-in-the-loop simulation
  • Device and circuit stimulus generation
  • Sensor and transducer simulation
  • Process and actuator control
  • Production and quality-control testing
  • Laboratory automation
  • Closed-loop control development
  • Research and development systems
  • Functional testing of electronic assemblies
  • PXI modular instrumentation systems

Product Overview

Brand NI / National Instruments
Model PXI-6713
Product Category High-Speed Analog Output Module
Analog Output Channels 8 voltage outputs
Output Resolution 12 bits
Maximum Update Rate 1 MS/s per channel on supported configurations
Output Range ±10 V or compatible external-reference scaling
Module Format 3U PXI / CompactPCI
Primary Application Multichannel waveform generation, stimulus, automation, and control

 

Analog Output Specifications

Specification Details
Number of Channels 8
Resolution 12 bits, one part in 4,096
DAC Type Double-buffered multiplying DAC
FIFO Size 16,384 samples
Nominal Output Range ±10 V
External Reference Range Compatible external reference up to ±11 V
Output Coupling DC
Maximum Output Impedance 0.1 ohm
Maximum Current Drive ±5 mA
Load Stability Compatible passive loads up to 1,500 pF
Output Protection Short-circuit protection to ground
Power-On Output State 0 V within ±200 mV

 

Maximum Update Rate by Active Channel Count

Active Channels Using Local FIFO Using Host Memory
1 to 5 1,000 kS/s per channel 1,000 kS/s per channel
6 952 kS/s per channel 1,000 kS/s per channel
7 833 kS/s per channel 869 kS/s per channel
8 740 kS/s per channel 769 kS/s per channel

 

Dynamic Performance

Specification Details
Slew Rate 20 V/µs
Settling Time 3.0 µs to ±0.5 LSB
Output Noise 200 µV RMS from DC to 1 MHz
Channel Crosstalk -70 dB using the documented cable and test conditions
Typical Total Harmonic Distortion -80 dB under the documented test conditions
Monotonicity 12 bits guaranteed after calibration

 

Digital and Timing Resources

Resource Details
Digital I/O 8 TTL/CMOS-compatible lines
Digital I/O Power-On State High-impedance input
Counter/Timers Two 24-bit up/down counters
Frequency Scaler Four bits
Counter Base Clocks 20 MHz and 100 kHz
Maximum Source Frequency 20 MHz
PXI Trigger Lines 6
PXI Star Trigger 1
PXI Clock 1

 

Physical and Environmental Specifications

Specification Details
Bus Interface PXI / CompactPCI
I/O Connector 68-pin male SCSI-II-type connector
Module Dimensions 16 x 10 cm
Typical Power Requirement +5 VDC at 1.25 A
Maximum Power Requirement +5 VDC at 1.5 A
Operating Temperature 0 °C to 50 °C
Storage Temperature -20 °C to 70 °C
Operating Humidity 5% to 90% RH, noncondensing
Maximum Altitude 2,000 m
Installation Environment Indoor use only

 

System Requirements

The NI PXI-6713 requires a compatible 3U PXI or CompactPCI chassis, system controller, supported NI driver environment, application software, and a suitable I/O cable or terminal block.

A compatible 68-pin cable provides access to the analog outputs, digital I/O, counter/timer signals, trigger connections, reference input, and grounds. Shielded cabling is recommended for controlled signal integrity and electromagnetic compatibility.

The connected device must remain within the module’s ±10 V output range, ±5 mA drive capability, and supported capacitive loading. The PXI-6713 is a voltage-output module and is not intended to directly power high-current loads.

Comprehensive Functional and Performance Testing

The NI PXI-6713 receives comprehensive functional and performance testing before shipment. Evaluation may include PXI chassis recognition, driver communication, onboard self-test, analog output generation, static voltage operation, buffered waveform output, digital I/O, counter/timer functions, and trigger resources.

Analog testing may include representative voltage measurements across all eight channels, output offset, linearity, waveform generation, settling behavior, and channel response using suitable calibrated measurement equipment.

The 68-pin connector, backplane connector, front panel, retaining hardware, printed circuit assembly, module shielding, labels, and identification markings may be inspected for contamination, bent contacts, corrosion, physical damage, unauthorized modification, or excessive wear.

The exact testing scope depends on the available PXI chassis, controller, driver version, I/O cable, terminal block, oscilloscope, digital multimeter, counter equipment, and requested output conditions.

Calibration Before Shipment

When technically applicable and selected, the NI PXI-6713 can be calibrated or performance-verified before shipment. Evaluation may include analog output voltage accuracy, offset, gain, linearity, monotonicity, digital I/O operation, and timing functions.

Calibration documentation should identify the module model and serial number, tested channels, commanded output levels, measured voltages, reference equipment, environmental conditions, recorded results, and applicable measurement uncertainty.

Buyers requiring formal calibration should specify the required output channels, voltage points, external-reference testing, certificate format, recorded results, and required measurement uncertainty before purchase.

Why Buy from AssetRelay?

AssetRelay supplies professional equipment and product solutions for automated measurement, data acquisition, electronic testing, telecommunications, laboratory, production, inspection, RF/microwave, photonics, and technical research applications. The NI PXI-6713 supports electronics manufacturers, test-system developers, laboratories, production facilities, system integrators, universities, and research organizations.

Buyers should review the eight analog outputs, 12-bit resolution, channel-dependent update rates, ±10 V range, FIFO capacity, digital and timing resources, PXI compatibility, I/O connector condition, functional test results, calibration status, and included accessories before purchase.