Wavelength-Ref · HCN-13-25
HCN-13-25 Hydrogen Cyanide Wavelength Reference Cell, 1525 to 1565 nm
$1,360.00
Price in USD.
- Condition
- New (open box)
- Availability
- In stock
- Model
- HCN-13-25
- Manufacturer
- Wavelength-Ref
- Category
- Visible and Other Laser Sources
Description
HCN-13-25 Hydrogen Cyanide Wavelength Reference Cell
The HCN-13-25 Wavelength Reference Cell is a precision hydrogen cyanide gas cell designed to provide stable molecular absorption references across the optical telecommunications C-band. Its specified wavelength range extends from 1525 to 1565 nm, making the cell suitable for wavelength calibration, verification, and analysis in professional fiber optic, telecom, photonics, laboratory, and production-test environments.
The cell uses H 13 C 14 N molecular absorption lines that have been identified by national standards bodies as primary wavelength references within the 1530 to 1565 nm C-band. These defined absorption features provide reference points that can be used to evaluate compatible wavelength-measurement instruments and optical sources.
The HCN-13-25 is supplied at a standard nominal pressure of 25 Torr. Pressure influences the absorption linewidth, while optical path length affects the measured absorption depth. The cell is hard-sealed for long service life and incorporates an advanced optical design intended to keep interference artifacts at very low levels.
Features and Benefits of the HCN-13-25
The HCN-13-25 provides a stable wavelength-reference solution for professional users working with C-band optical sources and measurement systems.
- C-band wavelength coverage: Supports wavelength referencing across a specified range of 1525 to 1565 nm.
- Hydrogen cyanide absorption reference: Uses H 13 C 14 N molecular absorption lines associated with defined molecular energy-level transitions.
- NIST-traceable reference: Provides traceable absorption features for wavelength calibration and verification applications.
- High wavelength accuracy: Specified expanded wavelength uncertainty is ±0.2 pm.
- Defined absorption depth: Provides a typical absorption-line depth of 3.2 dB.
- 25 Torr nominal pressure: The cell is configured at one of the standard available pressures for this wavelength-reference product family.
- Hard-sealed construction: Designed for long operational life and stable gas-cell performance.
- Low-interference optical design: Advanced optical construction helps maintain very low levels of interference artifacts.
Molecular Absorption Wavelength Referencing
Gas cells function as precision optical filters. When a broadband source or tunable laser passes through the cell, specific wavelengths are absorbed according to molecular energy-level transitions. These absorption lines form a characteristic spectrum that can be used as a stable wavelength reference.
The HCN-13-25 uses the absorption spectrum of H 13 C 14 N. Because the locations of the molecular absorption lines are defined by molecular properties, the cell can provide reference features for checking the wavelength accuracy of compatible optical measurement systems.
A typical measurement arrangement may include the wavelength reference cell, a suitable C-band optical source, and compatible wavelength-analysis equipment. Depending on the application, the resulting absorption spectrum can be used to identify known reference lines and compare those lines with the wavelength readings produced by the instrument under evaluation.
Pressure and Optical Path Considerations
The HCN-13-25 model is supplied at a nominal gas pressure of 25 Torr. Gas pressure affects the linewidth of the molecular absorption features. Users should account for the pressure configuration when selecting a reference cell for a particular wavelength-calibration or spectroscopy application.
Optical path length affects the measured depth of the absorption lines. Wavelength reference gas cells in this product family are available in two standard physical sizes, corresponding to optical path lengths of 5.5 cm and 16.5 cm. The exact path length associated with the specific HCN-13-25 unit should be confirmed before use when this parameter is important to the measurement procedure.
The typical absorption-line depth specified for the HCN-13-25 is 3.2 dB. Actual observed results can depend on the optical source, measurement instrument, coupling arrangement, wavelength resolution, polarization behavior, cell configuration, and overall test setup.
Typical Applications
The HCN-13-25 Wavelength Reference Cell is suitable for professional applications such as:
- C-band optical wavelength calibration
- Verification of wavelength-measurement instruments
- Tunable laser wavelength referencing
- Optical spectrum analyzer evaluation
- Telecommunications research and development
- Dense wavelength division multiplexing test environments
- Photonics laboratory measurements
- Optical source characterization
- Production and quality-control testing
- Development of wavelength-analysis systems
Product Overview
| Model | HCN-13-25 |
| Product Category | Wavelength Reference Gas Cell |
| Gas Species | Hydrogen cyanide, H 13 C 14 N |
| Nominal Gas Pressure | 25 Torr |
| Primary Application | C-band optical wavelength referencing and calibration |
| Traceability | NIST-traceable wavelength reference |
| Suitable For | Telecommunications laboratories, photonics research, optical test systems, production environments, and wavelength-instrument verification |
Specifications
| Specification | Details |
| Wavelength Range | 1525 to 1565 nm |
| Wavelength Accuracy | ±0.2 pm expanded uncertainty |
| Absorption-Line Depth | 3.2 dB typical |
| Molecular Species | H 13 C 14 N |
| Nominal Pressure | 25 Torr |
| Reference Type | NIST-traceable molecular absorption wavelength reference |
| Construction | Hard-sealed gas cell |
Optical Test-System Integration
The HCN-13-25 should be incorporated into a compatible optical setup capable of operating across the specified 1525 to 1565 nm wavelength range. A complete system may include a tunable laser or broadband source, fiber optic couplers, suitable optical cables, a detector, an optical spectrum analyzer, a wavelength meter, or other wavelength-analysis equipment.
Buyers should confirm the cell interface, optical path length, connector configuration, insertion requirements, source compatibility, and measurement-instrument resolution before integration. Optical cables, source equipment, analyzers, detectors, adapters, and mounting accessories should not be assumed to be included unless specifically identified in the product listing or quotation.
All optical interfaces should be inspected and cleaned before connection. Contamination, damaged connectors, unsuitable fiber, or poor coupling can reduce signal quality and affect the observed absorption spectrum.
Calibration and Traceability
The HCN-13-25 provides NIST-traceable molecular absorption references for C-band wavelength applications. The specified ±0.2 pm expanded uncertainty supports precise wavelength verification when the cell is used with compatible optical equipment and an appropriate measurement procedure.
The reference cell does not independently determine wavelength. The accuracy of the complete measurement process also depends on the optical source, measurement instrument, spectral resolution, signal-to-noise ratio, environmental conditions, optical coupling, and analysis method. Buyers requiring specific calibration documentation or verification of a complete wavelength-measurement configuration should communicate those requirements before purchase.
Why Buy from AssetRelay?
AssetRelay supplies professional equipment and product solutions for fiber optic, telecom, laboratory, production, inspection, RF/microwave, electronic test, laser, and photonics applications. The HCN-13-25 is listed to help engineers, technicians, metrology teams, procurement departments, laboratories, manufacturers, and service organizations source practical wavelength-reference equipment for professional optical systems.
Before purchase, buyers should review the specified wavelength range, nominal pressure, optical path-length requirements, wavelength uncertainty, absorption depth, interface configuration, calibration needs, product condition, and included accessories. Confirming these details helps ensure that the HCN-13-25 is appropriate for the intended wavelength-referencing, calibration, or optical test application.