JDS FITEL HA9-Z064 62.5/125 µm Multimode Variable Optical Attenuator

The JDS FITEL HA9-Z064 is a programmable variable optical attenuator configured for 62.5/125 µm multimode fiber. It is designed for precise optical signal-level control in laboratory, telecommunications, manufacturing, calibration, and automated test environments.

The attenuator provides an optical attenuation range from 0 dB to 100 dB across wavelengths from 1200 nm to 1700 nm. Attenuation can be adjusted with 0.01 dB settability at 1300 nm, supporting controlled optical power changes for receiver sensitivity testing, link-loss simulation, component characterization, and instrument verification.

A built-in optical on/off switch provides more than 110 dB of isolation and operates in less than 20 ms. This shutter allows the optical signal to be interrupted without changing the programmed attenuation setting or disabling the connected source.

The HA9-Z064 designation identifies a factory-configured instrument. The supplied product information establishes a 62.5/125 µm multimode fiber configuration. The exact connector type, front-panel port arrangement, backreflection configuration, and installed splitter or switch options should be verified directly from the individual unit.

Features and Benefits of the JDS FITEL HA9-Z064

  • 62.5/125 µm multimode fiber configuration: Supports compatible multimode optical sources, receivers, components, and test assemblies.
  • 100 dB attenuation range: Provides broad optical-level control for receiver and component testing.
  • 1200 nm to 1700 nm wavelength range: Supports compatible near-infrared multimode test applications.
  • 0.01 dB settability: Allows fine attenuation adjustment at 1300 nm.
  • High repeatability: Provides ±0.015 dB repeatability at constant temperature and wavelength.
  • Multimode insertion loss: Provides model-dependent insertion loss according to the numerical aperture of the installed fiber.
  • Low polarization sensitivity: Limits polarization-related variation to less than 0.1 dB peak-to-peak across the attenuation range.
  • Fast attenuation changes: Moves from 0 dB to 100 dB in 2.5 seconds or less.
  • Integrated optical shutter: Provides more than 110 dB of signal isolation.
  • Fast shutter response: Changes optical state in less than 20 ms.
  • High optical input capability: Supports optical input power up to 200 mW for the applicable multimode configuration.
  • Automated-test compatibility: Suitable for repeated attenuation sequences in laboratory and production systems.

0 dB to 100 dB Optical Attenuation

The JDS FITEL HA9-Z064 provides adjustable attenuation from 0 dB to 100 dB. This range allows the instrument to simulate both low-loss and high-loss optical paths without requiring repeated replacement of fixed attenuators.

Low attenuation settings are useful for making controlled adjustments to a strong optical signal. Higher settings support receiver sensitivity measurements, weak-signal simulation, detector testing, and system loss-budget evaluation.

The instrument changes from 0 dB to 100 dB in 2.5 seconds or less. This response supports optical-level sweeps and automated measurements requiring multiple attenuation points.

62.5/125 µm Multimode Fiber Configuration

The HA9-Z064 is configured for 62.5/125 µm multimode fiber. Compatible multimode patch cords and devices should be used throughout the optical path to preserve the intended launch conditions.

Multimode measurements can be affected by numerical aperture, connector alignment, modal distribution, source launch conditions, fiber bends, patch-cord routing, and detector geometry. Reference fibers and connection conditions should remain consistent during comparative measurements.

Single-mode patch cords should not be substituted when the test procedure requires controlled 62.5/125 µm multimode performance.

Attenuation Accuracy and Repeatability

Within the documented wavelength regions from 1280 nm to 1340 nm and from 1470 nm to 1550 nm, attenuation accuracy is specified at ±0.1 dB or ±0.004 dB per decibel of attenuation, whichever is greater.

Attenuation repeatability is specified at ±0.015 dB under constant temperature and wavelength conditions. This repeatability supports automated receiver testing, production screening, component qualification, and measurements that revisit the same attenuation settings.

Complete measurement uncertainty also depends on source stability, operating wavelength, multimode launch conditions, connector cleanliness, patch-cord condition, and the optical power meter used to verify the output.

Multimode Insertion Loss

Insertion loss depends on the numerical aperture of the multimode fiber configuration. The documented maximum insertion loss is 2.2 dB for multimode fiber with a numerical aperture of 0.2 and 2.9 dB for multimode fiber with a numerical aperture of 0.3.

These values exclude external connector loss and the additional losses of any optional switch or coupler installed in the optical path.

The specific numerical aperture of the HA9-Z064 should be confirmed when insertion-loss requirements are critical.

Built-In Optical Shutter

The HA9 incorporates a built-in optical on/off switch with more than 110 dB of isolation. The shutter interrupts the optical path without changing the programmed attenuation value.

The documented switching time is below 20 ms. This function supports dark measurements, receiver protection, automated measurement sequences, and rapid transitions between optical signal and no-signal conditions.

The shutter should not replace normal optical safety procedures. The connected source should still be disabled before connectors are inspected, cleaned, installed, or removed.

Optional Optical Configurations

The HA9 platform was available with several optional optical configurations. These included a 1 x 2 optical switch, a 50/50 optical splitter, and a 10/90 optical splitter.

If a 1 x 2 optical switch is installed, the instrument can select between two optical inputs or outputs. The HA9 documentation notes that the auxiliary 5 V output is not externally available when this switch is installed.

Optional splitter or switch functions should only be included in the final product configuration when the applicable hardware is physically present and verified.

Typical Applications

  • 62.5/125 µm multimode receiver sensitivity testing
  • Controlled optical loss simulation
  • Multimode transceiver testing
  • Optical detector characterization
  • Fiber optic component testing
  • Insertion loss and transmission measurements
  • Optical power meter linearity testing
  • Laboratory instrument calibration
  • Automated optical-level sweeps
  • Production screening and quality assurance
  • Telecommunications research and development
  • Optical test-system integration

Product Overview

Brand JDS FITEL
Model HA9-Z064
Product Series HA9 Series
Product Category Programmable Variable Optical Attenuator
Fiber Type 62.5/125 µm multimode fiber
Wavelength Range 1200 nm to 1700 nm
Attenuation Range 0 dB to 100 dB
Attenuation Settability 0.01 dB at 1300 nm
Optical Shutter Built-in on/off switch with more than 110 dB isolation
Primary Application Precise multimode optical signal-level control and loss simulation

 

Optical Specifications

Specification Details
Fiber Configuration 62.5/125 µm multimode fiber
Wavelength Range 1200 nm to 1700 nm
Attenuation Range 0 dB to 100 dB
Attenuation Settability at 1300 nm 0.01 dB
Attenuation Accuracy from 1280 nm to 1340 nm ±0.1 dB or ±0.004 dB per dB, whichever is greater
Attenuation Accuracy from 1470 nm to 1550 nm ±0.1 dB or ±0.004 dB per dB, whichever is greater
Attenuation Repeatability ±0.015 dB at constant temperature and wavelength
Maximum Optical Input Power 200 mW for the applicable multimode configuration
Polarization Sensitivity Less than 0.1 dB peak-to-peak across the attenuation range
Attenuation Change Time 2.5 seconds or less from 0 dB to 100 dB
Optical Shutter Isolation Greater than 110 dB
Optical Shutter Speed Less than 20 ms
Recalibration Period Not required in the documented HA9 specifications

 

Multimode Insertion Loss Specifications

Multimode Fiber Configuration Maximum Insertion Loss
Numerical Aperture 0.2 2.2 dB or less
Numerical Aperture 0.3 2.9 dB or less

 

Backreflection Specifications

Multimode Fiber Configuration Low-Backreflection Option
Numerical Aperture 0.2 Less than -40 dB, excluding connectors
Numerical Aperture 0.3 Less than -35 dB, excluding connectors

 

Environmental and Physical Specifications

Specification Details
Operating Temperature 0 °C to 40 °C
Storage Temperature -40 °C to +60 °C
Humidity Up to 95% relative humidity at 40 °C, decreasing by 5% per °C from 40 °C to 60 °C
Dimensions 35.5 x 21.2 x 8.9 cm
Weight 3.75 kg

 

Configuration Details Requiring Verification

Configuration Item Verification Required
Optical Connector Type Confirm the installed connector family and ferrule polish
Port Arrangement Confirm front-panel pigtails or bulkhead optical interfaces
Numerical Aperture Confirm the applicable multimode NA for insertion-loss and backreflection specifications
Backreflection Configuration Confirm the installed low-backreflection or other factory option
Optical Splitter Confirm whether a 50/50 or 10/90 splitter is installed
1 x 2 Optical Switch Confirm whether the optional SW12 input or output selector is installed

 

Measurement Setup

The JDS FITEL HA9-Z064 should be installed on a stable laboratory bench or in a suitable equipment rack with adequate clearance for ventilation, optical cables, communication cables, and AC power.

Compatible 62.5/125 µm multimode patch cords should be connected to the optical input and output. The connector family and ferrule polish must match the interfaces installed on the instrument.

All optical connectors should be inspected and cleaned before mating. A sensitive receiver or detector should initially be connected with the attenuator set to a high attenuation value.

The attenuation can then be reduced gradually while optical power and device response are monitored. The source wavelength should remain within the 1200 nm to 1700 nm operating range, and input power must remain below the documented 200 mW limit.

Comprehensive Functional and Performance Testing

The JDS FITEL HA9-Z064 receives comprehensive functional and performance testing before shipment. Evaluation may include AC power operation, startup, front-panel controls, display response, attenuation adjustment, optical shutter operation, and applicable remote-control functions.

Optical testing may include input-to-output continuity, insertion loss, representative attenuation values, attenuation repeatability, attenuation range, response time, and optical shutter isolation using compatible multimode sources and calibrated optical power meters.

The optical interfaces, pigtails or bulkheads, connectors, shutter, controls, display, communication ports, AC inlet, enclosure, labels, and installed options may be inspected for contamination, damage, corrosion, or excessive wear.

The exact testing scope depends on the verified connector type, port arrangement, numerical aperture, installed options, available multimode sources, reference patch cords, power meters, and requested wavelength and attenuation points.

Why Buy from AssetRelay?

AssetRelay supplies professional equipment and product solutions for fiber optic, telecommunications, optical testing, photonics, laboratory, production, inspection, electronic testing, RF/microwave, and technical research applications. The JDS FITEL HA9-Z064 provides controlled multimode optical attenuation for component manufacturers, receiver developers, telecommunications laboratories, production facilities, system integrators, universities, and research organizations.

Buyers should review the 62.5/125 µm multimode configuration, numerical aperture, wavelength and attenuation ranges, optical interfaces, insertion loss, shutter operation, installed options, functional test results, and included accessories before purchase.