Agilent Keysight 86106B Optical Electrical DCA Module 28GHz 86100 Scope Plug-in: Single-Mode Optical Channel with 40 GHz Electrical for High-Speed Telecom Compliance Testing
The Agilent Keysight 86106B Optical Electrical DCA Module 28GHz 86100 Scope Plug-in is a dual-channel plug-in for the 86100B Infiniium DCA mainframe, combining a 28 GHz single-mode optical channel with a 40 GHz electrical channel. Built with an integrated OC-192/STM-64 (9.953 Gb/s) reference filter,it is designed for engineers running standards-based transmitter compliance testing on high-speed SONET/SDH optical transceivers.
Key Features and Benefits of the Agilent Keysight 86106B Optical Electrical DCA Module 28GHz 86100 Scope Plug-in
- 28 GHz single-mode optical channel — Wide unfiltered bandwidth captures high-speed optical waveforms with 18 ps transition time for accurate pulse shape analysis.
- 40 GHz electrical channel with dual bandwidth modes — 18 GHz mode delivers best oscilloscope noise performance; 40 GHz mode provides high-fidelity display of fast waveforms.
- Reference filter — Built-in OC-192/STM-64 (9.953 Gb/s) reference filter supports standards-based SONET/SDH transmitter mask testing and eye-diagram compliance verification.
- 1000 to 1600 nm wavelength range — Calibrated at both 1310 nm and 1550 nm for full coverage of single-mode telecom test wavelengths.
- -7 dBm sensitivity for mask test — Handles low-power transmitter outputs and lossy test setups without requiring external optical amplification.
- Integrated average power monitor — Built-in optical power meter reads absolute power directly, with factory calibrated accuracy of ±5% ±100 nW ±connector uncertainty.
- 9/125 µm single-mode fiber input — Optimized for standard telecom single-mode fiber with user-selectable connector interface.
- 2.4 mm electrical input — Precision 50 O connector interface for high-fidelity electrical measurements up to 40 GHz.
- Optical DC accuracy ±4% of reading — Delivers trustworthy amplitude measurements referenced to the average power monitor.
Advanced Capabilities
The 86106B's integrated architecture is what makes it particularly valuable for high-speed transmitter compliance testing. The complete measurement path — photodiode, amplification, reference filter, and average power monitor — is calibrated as a system. External optical-to-electrical converters combined with discrete power meters introduce cascaded uncertainties, connector losses, and wavelength-dependent errors that are difficult to characterize. With the 86106B, the complete measurement path — photodiode, amplification, reference filter, and average power monitor — is calibrated as a system. This integrated architecture allows absolute power readings and extinction ratio measurements to be derived from a single calibrated measurement chain, reducing uncertainty compared with external optical-to-electrical converters6and standalone power meters.
The 40 GHz electrical channel is the other technical strength worth calling out. With 9 ps transition time in 40 GHz mode, the module captures high-speed serial signals and pulse edges that lower-bandwidth scopes would smooth over. The selectable 18 GHz mode drops the characteristic RMS noise floor to 0.25 mV, delivering the low-noise performance needed for small-signal measurements. For engineers characterizing 40G electrical interfaces or looking at fast electrical outputs from optical receivers, this dual-mode design eliminates the tradeoff between bandwidth and noise that single-bandwidth scopes force on the user.
Calibration and Quality Assurance
Every Agilent Keysight 86106B is calibrated prior to shipping to OEM specifications. The order includes a Calibration Certificate, Calibration Label, and full Calibration Data. This means the module arrives traceable, audit-ready, and ready to use straight out of the box — no need to schedule a calibration cycle before putting it into service.
Specifications
| Specification | Value |
|---|---|
| Module Type | Single-mode optical + electrical plug-in for 86100B DCA |
| Number of Optical Channels | 1 |
| Number of Electrical Channels | 1 |
| Optical Channel Unfiltered Bandwidth | 28 GHz |
| Optical Wavelength Range | 1000 nm to 1600 nm |
| Calibrated Wavelengths | 1310 nm and 1550 nm |
| Installed Reference Filter | OC-192/STM-64 (9.953 Gb/s) |
| Sensitivity (smallest average power for mask test) | -7 dBm |
| Optical Transition Time (10%–90%, calculated from TR = 0.48/BW) | 18 ps |
| Optical RMS Noise (Filtered, characteristic) | 10 µW |
| Optical RMS Noise (Filtered, maximum) | 15 µW |
| Optical RMS Noise (Unfiltered, characteristic) | 18 µW |
| Optical RMS Noise (Unfiltered, maximum) | 30 µW |
| Optical Scale Factor | 20 µW to 500 µW per division |
| Optical CW Accuracy (single marker) | ±50 µW ±4% of (reading - channel offset) |
| Optical CW Difference (two markers) | ±4% of delta |
| Optical CW Offset Range | +1 mW to -3 mW |
| Average Power Monitor Range | -27 dBm to +3 dBm |
| Factory Calibrated Power Accuracy | ±5% ±100 nW ±connector uncertainty (20°C to 30°C) |
| User Calibrated Power Accuracy | ±2% ±100 nW ±power meter uncertainty (< 5°C change) |
| Maximum Non-Destruct Average Input Power | 2 mW (+3 dBm) |
| Maximum Non-Destruct Peak Input Power | 10 mW (+10 dBm) |
| Fiber Input | 9/125 µm single-mode, user-selectable connector |
| Input Return Loss (HMS-10, fully filled fiber) | 30 dB |
| Electrical Channel Bandwidth | 18 GHz and 40 GHz (selectable) |
| Electrical Transition Time (10%–90%, calculated from TR = 0.35/BW) | 19.5 ps (18 GHz); 9 ps (40 GHz) |
| Electrical RMS Noise (characteristic) | 0.25 mV (18 GHz); 0.5 mV (40 GHz) |
| Electrical RMS Noise (maximum) | 0.5 mV (18 GHz); 1.0 mV (40 GHz) |
| Electrical Scale Factor | 1 mV to 100 mV per division |
| Electrical DC Accuracy (18 GHz, single marker) | ±0.4% of full scale ±2 mV ±1.5% of (reading - channel offset) |
| Electrical DC Accuracy (40 GHz, single marker) | ±0.4% of full scale ±2 mV ±3% of (reading - channel offset) |
| Electrical DC Difference (18 GHz, two markers) | ±0.8% of full scale ±1.5% of delta |
| Electrical DC Difference (40 GHz, two markers) | ±0.8% of full scale ±3% of delta |
| Electrical DC Offset | ±500 mV |
| Electrical Input Dynamic Range | ±400 mV (relative to channel offset) |
| Maximum Electrical Input Signal | ±2 V |
| Electrical Nominal Impedance | 50 O |
| Electrical Reflections (for 20 ps rise time) | 5% |
| Electrical Input Connector | 2.4 mm (male) |
| Available Optical Connector Options | Diamond HMS-10, FC/PC, DIN, ST, SC |
| Compatible Mainframe | Agilent 86100B Infiniium DCA |